• product_banner

China wholesale Ivd - Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay) – Bioantibody

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have a highly efficient team to deal with inquiries from customers. Our goal is "100% customer satisfaction by our product quality, price & our team service" and enjoy a good reputation among clients. With many factories, we can provide a wide range of Chikungunya Igg And Igm, Igm Brucella, Nt-Probnp, Should you be fascinated in any of our products and services, remember to do not hesitate to make contact with us. We're ready to reply you inside of 24 several hours soon after receipt of one's ask for and also to develop mutual un-limited advantages and organization in around potential.
China wholesale Ivd - Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay) – Bioantibody Detail:

Product details

Intended Use
This product is suitable for in vitro qualitative detection of Rotavirus & Adenovirus Antigens in human faecal samples.

Test Principle
1.The product is a lateral flow chromatographic immunoassay. It has two results Windows.
2.On the left for Rotavirus. It has two pre-coated lines, “T” Test line and “C” Control line on the nitrocellulose membrane. Rabbit anti-rotavirus polyclonal antibody are coated on the test line region and Goat anti-mouse IgG polyclonal antibody are coated on the control region. A colored test line is visible in the result window if Rotavirus antigens are present in the specimen and the intensity depends upon the amount of Rotavirus antigen. When the Rotavirus antigens in the specimen does not exist or is below the detection limit, there is not a visible colored band in the Test line (T) of the device. This indicates a negative result

Main Contents

Components provided are listed in the table.

Materials / provided Quantity (1 Test/Kit) Quantity(5Tests/Kit) Quantity(25Tests/Kit)
Test Kit 1 test 5 tests 25 tests
Buffer 1 bottle 5 bottles 25/2 bottles
Specimen Transport Bag 1 piece 5 pcs 25 pcs
Instructions For Use 1 piece 1 piece 1 piece
Certificate of Conformity 1 piece 1 piece 1 piece

Operation Flow

1.Remove a test cassette from the foil pouch and place on a flat surface.
2.Unscrew the sample bottle, use the attached applicator stick attached on the cap to transfer small piece of stool sample (3- 5 mm in diameter; approximately 30-50 mg) into the sample bottle containing specimen preparation buffer.
3. Replace the stick into the bottle and tighten securely. Mix stool sample with the buffer thoroughly by shaking the bottle for several times and leave the tube alone for 2 minutes.
4. Uncrew the sample bottle tip and hold the bottle in a vertical position over the sample well of the Cassette, deliver 3 drops (100 -120μL) of diluted stool sample to the sample well.
5. Read the results in 15-20 minutes. The result explanation time is not more than 20 minutes.

Result Interpretation

detail

Negative result
Colored band appear at control line (C) only. It indicates that the concentration of the Rotavirus or Adenovirus antigens do not exist or below the detection limit of the test.

Positive Result
1.Rotavirus Positive Result
Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the Rotavirus antigens in the specimen.
2.Adenovirus Positive Result
Colored bands appear at both test line (T) and control line (C). It indicates a positive result for the Adenovirus antigens in the specimen.
3. Rotavirus and Adenovirus Positive Result
Colored bands appear at both test line (T) and control line (C) in two windows. It indicates a positive result for the Rotavirus and Adenovirus antigens in the specimen.

Invalid Result
No visible colored band appears at control line after performing the test. The directions may not have been followed
correctly or the test may have deteriorated. It is recommended that the specimen be re-tested.

Order Information

Product Name Cat. No Size Specimen  Shelf Life Trans. & Sto. Temp.

Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay)

B021C-01 1test/kit Feces 18 Months 2-30℃ / 36-86℉
B021C-05 5 tests/kit
B021C-25 25 tests/kit

Product detail pictures:

China wholesale Ivd - Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay) – Bioantibody detail pictures

China wholesale Ivd - Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay) – Bioantibody detail pictures


Related Product Guide:

As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for China wholesale Ivd - Rotavirus & Adenovirus Antigen Combo Rapid Test Kit (Immunochromatographic Assay) – Bioantibody , The product will supply to all over the world, such as: Lithuania, Uruguay, Irish, Besides strong technical strength, we also introduce advanced equipment for inspection and conduct strict management. All the staff of our company welcome friends both at home and abroad to come for visits and business on the basis of equality and mutual benefit. If you are interested in any of our items, please feel free to contact us for quotation and product details.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Julie from Munich - 2018.02.12 14:52
    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Lillian from Leicester - 2018.12.11 14:13
    Write your message here and send it to us